• Low Voltage Speed Control

Index of Speed Control

B-LV12
MAX  20A(250W)
B-LV24
MAX  20A(500W)
  • Using over 10A, please with cooling fan

 


Usage and funcions:

    When S4、S5 control the ON/OFF, the voltage output by M+, M- will be cut off immediately.

  • Once the control has been stopped working for long time, please turn off the power.
  • The voltage (0-9VDC) of speed control can replace potential counter and control. Please connected across V2(+) and V1(-).
  • Please install signal isolator, when it controlled by voltage, it will prevent the interference of potential difference.
  • When it is controlled by voltage, MAX cannot work.
  • LV(輸入最低電壓)(12V)LV≤9.6V,(24V)LV≤19.2V。
  • Green light:Power light
  • Yellow light:The input voltage less than 80% the yellow light will light up.
  • Red light:When the electric current overload, please press the Reset back.Reset鍵復歸。

 

Setting of Property Adjustment :

  • MIN (Minimum rotation rate): 30%CL (Electric current adjustment): 50% 
  • MAX (Maximum rotation rate): 70%ACCEL (Acceleration): 50% 
  • LV (Minimun input low voltage): 80% 

 


Range Property Adjustment :

  • Electrical current set (%)........................................................................150-200
  • Accelerating time (0-fully load) (second)....................................................0.5-4.0
  • Adjustment range of minimum rotation rate (% fully load)...............................0-30
  • Adjustment range of maximum rotation rate (% fully load)...........................50-100
  • Input of minimum voltage................................................................................80
  • Range of rotation rate (ratio)........................................................................30:1
  • The highest permission of fully rotation ambient temperature (°C°/F)............42/113